Register

Portable Oxygen Systems

Its the carry case, stupid. Nelson has the best and since the systems are functionally alike, theyre our choice.

The use of supplemental oxygen pilots is growing, perhaps fed by an increasing awareness of how dangerous hypoxia can be and the availability of inexpensive pulse oximeters that show just how oxygen deficient you can get, even at low altitudes.

Just as when we last examined these products six years ago, our evaluation shows that all the systems we looked at will provide a reliable source of oxygen.

The changes in equipment available today are relatively minor and the improvements and differences are in the details-details that make a difference in convenience, value, and in some instances, safety.

Four Sources
There are still four players in this market, Aerox, Aircraft Industries (Sky Ox), Mountain High Equipment & Supply (MHE&S) and Precise Flight (Nelson). Precise Flight bought Nelson in 1998, making few changes in the product line. Selecting a system can be confusing, since there are many similarities between the products and many share the same components.

Your first decision will be size. Two-person systems are a bit less expensive because a smaller cylinder is often used and there are fewer cannulas and masks to purchase.

MHE&S is unique in its wide choice of cylinders for the same price. However, except for Mountain Highs electronic EDS systems, the incremental cost of upgrading to a four-person system isn’t much, while upgrading later can cost a good deal more, regardless of the system. Advice: If you think you’ll ever need oxygen for four, buy it at the outset. you’ll probably save money.

The second criteria is system management. Will one person manage it for everyone or do you want to allow individuals to manage their own oxygen? The standard Sky Ox system is designed around the former philosophy, the rest subscribe to the latter.

Before deciding, understand that individual oxygen needs vary, thus a single oxygen flow setting may result in higher consumption than necessary for one person, too little for another.

With individual adjustment, each user can set the flow rate to what they require, which we think is the better solution, given individual differences.Portability is an issue, too. Some portable systems are installed with brackets holding the cylinder to the floor or sidewall. Its removed only for filling, maybe, and the case may or may not be used for transporting the cylinder.

Commonalities
All the aluminum cylinders used by the suppliers are basically the same. The differences are in volume and dimensions. Volume is related to system size and duration required. Most two- and four-person systems use 22 to 24 cubic foot cylinders and wed recommend that size as a minimum.

We suggest getting the largest cylinder you can afford, in cost, size and weight. Kevlar-wound aluminum cylinders are available for significantly more money and 50 percent weight savings may be worth it to some. Aerox, MHE&S and Nelsons Sportsman systems all use essentially the same piston style regulator, compact, simple and reliable. With the exception of the MHE&S EDS system, all provide Chad conserving cannulas. If you don’t like their standard style, theyll give you the other style for no extra cost.

All use similar basic non-rebreather style soft plastic masks (bag attached) except for the MHE&S EDS mask, which dispenses with the bag. The masks are uncomfortable enough that many avoid their use, either limiting flight to 18,000 feet and below or using cannulas above that altitude, despite regulations to the contrary.

Aerox and Sky Ox provide only a single mask for the pilot as standard equipment. With Nelson and MH systems, everyone gets a mask.

Aerox
The Aerox regulator has its small brass quick connectors protruding out of the top of the body. With the cylinder mounted on the seat back, these present a potential danger to a rearseat passenger, something that wouldnt be a problem if the unit were semi-permanently installed on its side.

Aerox offers two flow adjustment systems using the same brass needle valve. We like that brass valve for its inherent strength and resistance to damage and deterioration. In the standard system, the valve is located on the male quick connect fitting at the regulator.

A dual-range (cannula and mask) 22,000- foot flowmeter is located at the other end of the supply line and the cannula or mask attach to the outlet. With this design, there’s no high pressure in the hose from the regulator to a remote valve, a good feature.

The Aerox case is constructed of lightweight nylon material laminated to 3/16 inch insubstantial foam with a lightweight fuzzy lining bonded to the foam. There’s nothing to retain the cylinder in the case, so if the zipper is open, it could come out in transport or in turbulence.

Also, the harness straps made it difficult to operate the shutoff valve. The mounting harness is a poor knock-off of Nelsons, in our view, and attaching and removing it with a 22-cubic foot cylinder was awkward due to the webbing design. No storage for cannulas or masks is included. Aerox provided a sample of its Quick Donning Type, Double Seal Silicon Mask with electret microphone. This same Aerox mask was also supplied by Nelson and Sky Ox. It proved comfortable and provided better sound quality than any other such mask we have tried.

Whether its worth $385 is questionable, although one volunteer tester purchased the unit he tested for his own use. A less expensive option is the same mask, sans microphone for $120. Its equipped with a diaphragm that allows you to be heard through the mask and to use your mic. Sound quality suffers, but its readable.

We got sound quality equivalent to these expensive masks by slipping a headset mic through cross slits cut in the side of the standard mask (with no noticeable reduction in oxygenation). Not elegant, but effective.

Sky Ox
Upfront we’ll mention this systems most significant failing: Its case, which we feel makes it unacceptable for portable use. While Sky Ox claims the bag can be used to secure the system, it has only a shoulder strap, with no other means to fasten it securely.

The bag has a clear plastic window so you can check the cylinder pressure without opening it and a drawstring bag is included for cannulas and mask storage.

Sky Ox is the only manufacturer who supplies the pendant style conserving cannula as standard.

Flexible plastic loops go over the ears and we found them surprisingly comfortable for the most part. The pendants nasal tubes are more comfortable without the reservoir and this allows you to drink without removing the cannula, important because oxygen dries you out.

With the Sky Ox system, flow rate is set at the regulator for all users. The gauge is marked in both flow rates (liters per minute) and altitude. A instruction sheet provided explains LPM settings but reading closely reveals that the altitude markings are for mask use only, while cannula use isn’t explicitly marked. We think it would be better to annotate the gauge for both cannula and mask and not rely upon a slip of paper thats sure to be lost.

Mountain High
We tested two systems from Mountain High, a conventional system using Nelson A4 flowmeters and conserving cannulas and their unique EDS Electronic Pulse-Demand Oxygen Delivery System.

As far as the conventional system goes, the only significant difference between MHE&S and Nelson is that MHE&S uses Delrin fittings instead of plated metal at the regulator.

Since we were testing to 24,000 feet, our system was equipped with A4 dual-scale flowmeters. A3 flowmeters are for use only with cannulas to 18,000 feet and are options.

Patrick McLauglin, President of MHE&S, told us that they have designed new flowmeters that address the various failure modes of the Nelson units and these are supposed to be available this fall.

MHE&S supplied a Scott mask with electret microphone for use with its conventional system but we found it all but useless and uncomfortable. The head strap naturally falls over the ear, a poor design thats annoying to wear. The mic made for unintelligible sound quality.

The EDS D1 system is a second-generation unit using a digital rather than analog design and its smaller and lighter than the original we tested a few years ago. In brief, it provides oxygen on demand at the beginning of each inhalation, as opposed to a constant flow of oxygen in the conventional systems. By providing no more than is needed, oxygen duration is claimed to be extended as much as 30 to 60 percent over conserving cannulas.

The EDS D1 connects to the standard MHE&S regulator and runs for about 40 hours on a 9-volt battery but the battery will deplete quickly if not removed when the unit is idle. Alternatively, aircraft power can be used through a surge-protected power supply that sells for $195. Oxygen from the cylinder is supplied to the inlet and the delivery device, a standard (not conserving) cannula or mask, is attached to the outlet. Each person requires his own EDS unit.

Automatic Oxygen
The units solid-state temperature and baro sensors allow it to calculate pressure altitude to determine how much oxygen to supply. It senses the start of inhalation and delivers a pulse of oxygen, theoretically adequate for the pressure altitude.